欢迎访问《电化学(中英文)》期刊官方网站,今天是 分享到:

电化学(中英文) ›› 2023, Vol. 29 ›› Issue (7): 2216001.  doi: 10.13208/j.electrochem.2216001

• 教程 • 上一篇    下一篇

基于从头算分子动力学的金属/氧化物-水界面能带排列

庄永斌, 程俊*()   

  1. 固体表面物理化学国家重点实验室,厦门大学能源材料化学协同创新中心,厦门大学化学化工学院,福建 厦门 361005
  • 收稿日期:2022-06-20 修回日期:2022-07-11 接受日期:2022-09-02 出版日期:2023-07-28 发布日期:2022-07-15
  • 通讯作者: * Tel: (86)15711503716, E-mail: chengjun@xmu.edu.cn
  • 基金资助:
    国家自然科学基金项目(22021001);国家自然科学基金项目(21991151);国家自然科学基金项目(21991150)

Band Alignments of Metal/Oxides-Water Interfaces Using Ab Initio Molecular Dynamics

Yong-Bin Zhuang, Jun Cheng*()   

  1. State Key Laboratory of Physical Chemistry of Solid Surfaces, Collaborative Innovation Center of Chemistry for Energy Materials, Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, Fujian, China
  • Received:2022-06-20 Revised:2022-07-11 Accepted:2022-09-02 Published:2023-07-28 Online:2022-07-15

摘要:

金属/氧化物的界面能带排列对于理解电化学界面有至关重要的作用。本文介绍了如何基于从头算分子动力学模拟得到金属/氧化物-水界面的能带排列。计算能带排列可与实验能带排列直接进行比较,以获得该电位下分子层面上的理解。金属界面的能带排列可与实验测定的零电荷电位对比,半导体氧化物界面的能带排列可与实验上零电荷点下测定的平带电势相比较。

关键词: 能带排列, 金属-水界面, 氧化物-水界面, 从头算分子动力学

Abstract:

Band alignments of electrode-water interfaces are of crucial importance for understanding electrochemical interfaces. In the scenario of electrocatalysis, applied potentials are equivalent to the Fermi levels of metals in the electrochemical cells; in the scenario of photo(electro)catalysis, semiconducting oxides under illumination have chemical reactivities toward redox reactions if the redox potentials of the reactions straddle the conduction band minimums (CBMs) or valence band maximums (VBMs) of the oxides. Computational band alignments allow us to obtain the Fermi level of metals, as well as the CBM and VBM of semiconducting oxides with respect to reference electrodes. In this tutorial, we describe how to obtain the band alignments using ab initio molecular dynamics simulations. To be simple, we introduce the protocol of computational band alignments through two selected charge-neutral interfaces, i.e., Cu(100)- and SnO2(110)-water interfaces. It should be bear in mind that one can also apply this protocol to electrified interfaces. The band alignments at charge-neutral interfaces have different meanings for metals and semiconducting oxides. For metals, the alignments amount to Potentials of Zero Charge of metals, under which the metal-water interfaces possess zero net charge. For semiconducting oxides, the alignments show the positions of CBMs and VBMs under a special pH and potential. The special pH is named as Point of Zero Charge and the special potential is called Flat-Band Potential. The oxides-water interfaces have zero net charge if they are at the special pH and potential. It is worth noting that neither the positions of CBMs nor VBMs are directly interpreted as applied potentials. In the protocol, we refer computed levels to standard hydrogen electrode (SHE), and thus directly compare the levels with those from electrochemical experiments. With PBE functional, the computed Fermi level of Cu(100) is -0.726 V with respect to SHE and matches the experimental determination of -0.73 V (SHE). The CBM and VBM of SnO2(110), however, are computed as 1.76 V and 0.6 V (SHE), respectively, which fails to match the experimental values of 3.747 V and 0.147 V (SHE), respectively. We attribute the failure to the delocalization error of density functional theory. Because of the error, DFT tends to spatially delocalize one-electron orbitals, which occasionally has negligible influences on the Fermi level of metal, but significantly underestimates the band gaps of semiconducting oxides.

Key words: Band alignment, Metal-water interfaces, Oxides-water interfaces, Ab initio molecular dynamics