欢迎访问《电化学(中英文)》期刊官方网站,今天是
研究论文

薄层流动时安法测定电镀废水中的铜

  • 林新华
展开
  • 福建医科大学药学系,福建医科大学药学系 福建福州350004 ,福建福州350004

收稿日期: 2002-02-28

  修回日期: 2002-02-28

  网络出版日期: 2002-02-28

Determination of Copper in the Waste Water of Plating by Chronocoulometry for Flowing Solution

  • LIN Xin_hua
Expand
  • (Department of Pharmaceutical,Fujian Medical University,Fuzhou 350004,China

Received date: 2002-02-28

  Revised date: 2002-02-28

  Online published: 2002-02-28

摘要

应用薄层流动时安法测定电镀废水中铜的含量 .试样溶液由流动状态转换为静止状态时的时库仑电量与铜离子浓度 (2~ 16mg/L)呈良好的线性关系 .对样品溶液进行 8次平行测定的相对标准偏差小于 0 .1% ,标准加入法测定的回收率为 99%~ 10 3% .该方法克服了电容电流及电极表面性质改变等噪声干扰 ,具有快速灵敏、准确、再现性好的优点

关键词: 流动时安法; ; 测定

本文引用格式

林新华 . 薄层流动时安法测定电镀废水中的铜[J]. 电化学, 2002 , 8(1) : 100 -104 . DOI: 10.61558/2993-074X.1448

Abstract

The chronocoulometry for flowing solution was devoloped and applied to the detemination of copper(Ⅱ) in the waste water of plating.The linear range of copper(Ⅱ) was 2~16mg/L,and the relative standard deviation was less than 0.1% ( n =8).The recovery was 98%~103% for copper(Ⅱ) in the waste water.Chronocoulometry for flowing solution overcomed noise disturbance resulting from capacity current and variety of property of electrode surface.This method was sensitive,accurate and well reproducible.

参考文献

[1] GUOZhong_xian.Spectrophotometricdeterminationofmicroamountsofcopperbyflowinjectionanalysis[J].JournalofAnayticalScience(inchinese),1997,13(3):228(inchinese). [2] LIUJia_qin,KUANGYun_yan,XUQi_heng.Newinhibition_kineticspectrophotometricdeterminationoftracecopper(Ⅱ)[J].ChineseJournalofAnalyticalChemistry,1998,26(10):1285(inchinese). [3] SanAndresMP ,MarinaML .Spectrophotometricdeterminationofcopper(Ⅱ),nickel(Ⅱ)andcobalt(Ⅱ)ascomplexeswithsodiumdiethyldithiocarbamateincationicmicellarmidiumofhexadecyltrimethylammoniumsalts[J].Talanta,1994,41(2):179. [4] WANGZhao_hong.AZeemangraphitefurnaceatomicabsorptionspectrometricmethodforthedeterminationoftracecopperandchromiumindrinkingwater[J].SpectrocopyandSpectralAnalysis(inchinese),1999,19(4):616~618(inchinese). [5] JIANGChong_qiu,TANGBo,FUHong_yan,etal.Studyondeterminationofcopper(Ⅱ)withSalicylaldehydephenylhydrazonebyspectrophotofluorimetry[J].ChemicalJournalofChineseUniversities,1996,17(1):49(inchinese). [6] ZHANGMing_hao,ZHOUChun_shan,LIZhi_hong,etal.Rapidandsimultaneousdeterminationoftracecop per,cadmiumandcobaltinzincelectrolytesoultionbyoscillopolarography[J].ChineseJournalofAnalyticalChemistry,2000,28(8):997(inchinese). [7] HUZhe_song,ZHANGYi_ding.StudyonthepolarographicwaveofthecomplexbetweenCu(Ⅱ)and7_iodo_8_hydroxyquinoline_5_sulfonicacid[J].PhysicalTestingandChemicalAnalysis(PartB :ChemicalAnalysis),1993,29(6):360(inchinese). [8] NationalEnvironmentalProtectionAgency.Analysismethodofwaterandwastewatermonitoring[S].Beijin:ChinaEnviromentPress,1989.213(inchinese). [9] ZHANGRong_kun,LUOYing_hua.Studiesontheconstant_potentialchronoamperometryinthecaseoflami naflow[J].ChemicalJournalofchineseUniversities,1981,2(3):301(inchinese)
文章导航

/