研制一种新型二氧化锰-酶修饰碳糊电极.应用直接电位法分别研究了磷酸盐底液的pH值、不同种类的粘合剂、二氧化锰修饰含量以及温度等各因素对该修饰电极测定H2O2和葡萄糖电位响应的影响.在优化实验条件(35℃,磷酸缓冲底液pH=7)下,葡萄糖检测的线性范围为2.0×10-5~5.2×10-3mol.L-1,灵敏度:36.12~34.62 mV/pG lucose,检测限:3.3×10-6mol.L-1.该电极具有良好的选择性、灵敏度、稳定性和重复性,大多数常见阴阳离子、甘露醇、丙三醇和脲不干扰测定.
A novel carbon paste electrode(CPE) modified with MnO2 and glucose oxidase(GOx),is reported.Different factors,such as the effect of supporting electrolyte,pH of solutions,various paste glues,the amount of MnO2 and temperature,which may influence the determination of H2O2 and glucose were tested to optimize.Based on above,potentiometric determination of glucose was achieved in neutral solution and at 35 ℃,the electrode gave a response of 36.12~34.62 mV/pGlucose between 2.0×10-5mol·L-1 and 5.2×10-3 mol·L-1 with a detection limit of 3.3×10-6 mol·L-1.Moreover,this kind of the electrode had good stability and reproducibility.Most normal anion,cation,isotol,glycerin and amide will not interfere the determination of glucose.
[1]Janata J,Josowicz M,Vanysek P,et al.Chemical sen-sors[J].Anal Chem,1998,70:179R.
[2]Wang J.Electroanalysis and biosensors[J].AnalChem,1999,71:328R.
[3]Zhu L,Li Y Z,Ci Y X.Microbial based sensor for themeasurement of glucose in sermn and urine[J].ActaChimica Sinica,2002,04:23.
[4]Henry C.Getting under the skin:implantable glucosesensors[J].Anal Chem,1998,70:594A.
[5]Kirk J K,Rheney C C.Important features of blood glu-cose meters[J].J Am Pharm Assoc,1998,38:210.
[6]Clark LC,Lyons Jr C.Electrode systems for continuousmonitoring in cardiovasculasurgery[J].Ann NY AcadSci,1962,102:29.
[7]Soldatkin A P,El'skaya A V,Shul'ga A A,et al.Glu-cose sensitive conductometric biosensor with additionalNafion membrane:reduction on influence of buffer ca-pacity on the sensor response and extension of its dy-namic range[J].Anal Chim Acta,1993,283:695.
[8]Kharitonov A B,Zayats M,Lichtenstein A,et al,En-zyme monolayer-functionalized field-effect transistors forbiosensor applications[J].Sens Actuators B.2000,70:222.
[9]Yin L T,Chou J C,Chung W Y,et al.Glucose EN-FET doped with MnO2powder[J].Sens Actuators B,2001,76:187.
[10]Shul'ga A A,Koudelka-Hep M,Rooij de,et al.Glu-cose-sensitive enzyme field effect transistor using potas-sium ferricyanide as an oxidizing substrate[J].AnalChem,1994,66:205.
[11]Zhang H(张宏),Jin B K(金葆康),Jin X Y(金晓燕).The study of electrochemical behavior of dopa-mine at nano-gold modified carbon fiber electrode[J].Chinese Chemical Letters(in Chinese),2003,07:49.
[12]Silvia A Miscoria,Gustavo D Barrera,Gustavo A Ri-vas et al,Analytical performance of a glucose biosensorprepared by immobilization of glucose oxidase anddif-ferentmetals into a carbonpasteelectrode[J].Electroa-nalysis,2002,14(14):981.
[13]Wang J,Naser N,Angnes L,et al.Metal-dispersedcarbon paste electrodes[J].Anal Chem,1992,64:1285.
[14]Schachl K,Turkusˇic E,Komersova A,et al.Thethree-electrode configurations are planer Beckman mod-el[J].Collect Czech Chem Comm,2002,67:302.
[15]Karayakin A A,Kotel'nikova E A,Lukachova L V,etal.Optimal environment for glucose oxidase in perfluo-rosulfonated ionomer membranes:Improvement of first-generation biosensors[J].J Anal Chem,2002,74:1597.
[16]Zheng X W,Guo Z H.Flow-injection chemilumines-cence determination of quinine using on-line electro-generated cobalt(Ⅲ)as oxidant[J].Talanta,2000,50:1157.
[17]Luo Xi-Liang,Xu Jing-Juan,Zhao Wei,et al.A no-vel glucose ENFET based on the special reactivity ofMnO2nanoparticles[J].Biosensors and Bioelectron-ics,2004,19:1295.
[18]Luo Xi-Liang,Xu Jing-Juan,Zhao Wei,et al.Glu-cose biosensor based on ENFETdoped with SiO2nano-particles[J].Sensors and Actuators B,2004,97:249.