欢迎访问《电化学(中英文)》期刊官方网站,今天是
研究论文

溴酚蓝修饰玻碳电极测维生素C中抗坏血酸含量

  • 张述林 ,
  • 李敏娇 ,
  • 罗祎 ,
  • 王晓波
展开
  • 四川理工学院材料与化学工程系,四川理工学院材料与化学工程系,四川理工学院材料与化学工程系,四川理工学院材料与化学工程系 四川自贡643000,四川自贡643000,四川自贡643000,四川自贡643000

收稿日期: 2008-02-28

  修回日期: 2008-02-28

  网络出版日期: 2008-02-28

The Determination of Vitamin C by Bromophenol Blue Modified Glassy Carbon Electrode

  • ZHANG Shu-lin ,
  • LI Min-jiao ,
  • LUO Yi ,
  • WANG Xiao-bo
Expand
  • (Dept.of Material & Chemical Engineering,Sichuan University of Science & Engineering,Zigong 643000,Sichuan,China

Received date: 2008-02-28

  Revised date: 2008-02-28

  Online published: 2008-02-28

摘要

使用溴酚蓝修饰的玻碳电极,以快速循环伏安法测定维生素C片剂中抗坏血酸含量并优化实验条件.结果表明,溴酚蓝(BPB)修饰玻碳电极用于抗坏血酸含量的分析,有良好的稳定性和抗干扰能力.在0.0050~0.1500 g.L-1浓度范围内,峰电流与浓度呈良好的线性关系,R=-0.9991,检出限为0.0010 g.L-1,结果令人满意.

本文引用格式

张述林 , 李敏娇 , 罗祎 , 王晓波 . 溴酚蓝修饰玻碳电极测维生素C中抗坏血酸含量[J]. 电化学, 2008 , 14(1) : 100 -103 . DOI: 10.61558/2993-074X.1872

Abstract

The content of ascorbic acid of(vitamin C) was analyzed by using fast cyclic voltamment with bromophenol blue(BPB) modififed GC-electrode,and which experimental conditions were optimiged.The results showed that the BPB modified GC-electrode had the good stability and anti-jamming faculty for analysing the content of ascorbic acid.A linear relationship between the peak current and concentration of vitamin C in the range of 0.0050~0.1500 g·L-1 was obtained,which related coefficient and the detection limit are-0.9991 and 0.0010 g·L-1,respeclively.The method has satisfactory results.

参考文献

[1]Huang Guang-rong(黄光荣).The determination of as-corbic acid content in fruits or vegetables with toluidineblue spectrophotometry[J].Science and Technology ofFood Industry(in Chinese),2005,26(5):169-170. [2]Tong Chang-lun(童裳伦),Xiang Guang-hong(向光宏),Liu Wei-ping(刘维屏).Determination of ascorbicacid by indirect fluorimetry[J].Spectroscopy andSpectral Analysis(in Chinese),2005,25(4):598-600. [3]Zhuo Qiu-yu(朱秋毓),Ding Feng(丁峰),Yu Mao-hua(俞茂华),et al.Determination of vitamin C inplasma and dialysate from uremia patients by perform-ance liquid chromatography with electrochemical detec-tion[J].Chinese Journal of Chroma tography(in Chi-nese),2002,20(2):151-155. [4]Bseda A.A facile and sensitive spectrophotometric de-termination of ascorbic acid[J].Talanta,1987,34:731. [5]Huang Yan-sheng(黄燕生),Chen Jing(陈静),XuBing(许兵),et al.L_lysine modified glassy carbon e-lectrode for the detection of dopamine in the presence ofascorbic acid[J].Chemistry(in Chinese),2006,69(9):656-660. [6]Chen Song-lin(陈松林),Xue Lei(薛磊).Determina-tion of the contents of vitamin C by the method of thedressed vitreous carbon electrode and dissolving out vol-tammetry[J].Journal of Henan University(MedicalScience,in Chinese),2005,24(3):14-15. [7]Chen Wei(陈伟),Luo Hong-bin(罗红斌),Lin Xin-hua(林新华).Preparation of poly(BromophenolBlue)modified glassy carbon electrode and its electro-catalytic activity[J].Electrochemisry(in Chinese),2005,11(1):92-95.
文章导航

/