以Ti板阴极、Ti/Pt阳极组成无隔膜电解装置,电解低浓度NaCl溶液制得活性氯.研究电解时间、电流密度、氯离子浓度、溶液pH值对活性氯浓度及电流效率的影响.结果表明:电解时间增加,活性氯浓度增加,而电流效率逐渐降低;初始阶段活性氯浓度增加较快,近1 h活性氯浓度趋于稳定;增加氯化钠浓度可提高活性氯浓度和改善电流效率;微酸性电解液有利于提高活性氯浓度.电解过程中,溶液电导率不断降低,pH值变化范围在1之内.
Electrogeneration of active chlorine from diluted NaCl solutions was investigated in an undivided cell with Ti/Pt anode and Ti plate cathode.The effects of electrolysis time,current density(i),chloride concentration and pH value on the electrogeneration of active chlorine and current efficiency(CE) were analyzed.Meanwhile,the changing trends of the electrolyte's conductivity(TSD) and pH value in the electrolysis process were discussed.The results showed that the concentration of active chlorine increased with electrolysis time,but the trend became slow.During this process,the current efficiency reduced steadily.When i was 4.93~7.39 mA/cm2,the concentration of active chlorine increased with the increase of i,but no longer increased when the i exceeded 7.39 mA/cm2.The concentration of active chlorine and CE increased with the increase of NaCl concentration,but the increased range reduced.Acidic electrolyte was beneficial to electrogeneration of active chlorine.During the electrolysis,the TSD decreased steadily and the change of pH value did not exceeded 1.
[1]Yang C H,Lee C C,Wen TC.Hypochlorite generationon Ru-Pt binary oxide for treatment of dye wastewater[J].Journal of Applied Electrochemistry,2000,30(9):1043-1051.
[2]Rajkumar D,Palanivelu K.Electrochemical degradationof cresols for wastewater treatment[J].Industrial&En-gineering Chemistry Research,2003,42(9):1833-1839.
[3]Polcaro A M,Palmas S,Renoldi F,et al.On the per-formance of Ti/SnO2and Ti/PbO2anodes in electro-chemical degradation of 2-chlorophenol for wastewatertreatment[J].Journal of Applied Electrochemistry,1999,29(2):147-151.
[4]Rodgers J D,Jedral W,Bunce N I.Electrochemicaloxidation of chlorinated phenols[J].Environmental Sci-ence&Technology,1999,33(9):1453-1457.
[5]Qin G F,Li Z Y,Chen X D,et al.An experimentalstudy of an NaClO generator for anti-microbial applica-tions in the food industry[J].Journal of Food Engineer-ing,2002,54(2):111-118.
[6]Bergmann M E H,Koparal A S.Studies on electro-chemical disinfectant production using anodes containingRuO2[J].Journal of Applied Electrochemistry,2005,35(12):1321-1329.
[7]HUANG Y T(黄运涛),PENG qiao(彭乔).Influenceof the composition of sea water to the sea water direct e-lectrolysis[J].Liaoning Chemical Industry(in Chi-nese),2005,34(6):237-240.
[8]Vlyssides A G,Karlis K,Rori N,et al.Electrochemi-cal treatment in relation to pHof domestic wastewater u-sing Ti/Pt electrodes[J].Journal of Hazardous Materi-als,2002,95(1/2):215-226.
[9]Chen J J(陈佼骄),Du Min(杜敏),Han Bing(韩冰).Determination of effective chlorine density in elec-trolyzed seawater by DPD spectrophotometric method[J].Industrial Water Treatment,2006,26(8):66-69.
[10]Bechtold T,Turcanu A,Campese R,et al.On-siteformation of hypochlorite for indigo oxidation-scale-upand full scale operation of an electrolyser for denimbleach processes[J].Journal of Applied Electrochem-istry,2006,36(3):287-293.
[11]Kraft A,Stadelmann M,Blaschke M,et al.Electro-chemical water disinfection-Part I:Hypochlorite pro-duction from very dilute chloride solutions[J].Journalof Applied Electrochemistry,1999,29(7):861-868.
[12]LI X P(李晓萍),LIN H B(林海波),WU yan(吴岩),et al.Investigation on electrogenerated activechlor ine from NaCl solutions at Ti/PbO2anode[J].Journal of Jilin University(Science Edition)(in Chi-nese),2005,43(3):358-362.
[13]HUANG Y T(黄运涛),PENG qiao(彭乔).Study oneffects of electrode gap and velocity on positive pole insea water electrolysis[J].Liaoning Chemical Industry(in Chinese),2005,34(11):471-473.