欢迎访问《电化学(中英文)》期刊官方网站,今天是
研究论文

聚乙烯醇微透镜阵列的制备及其固载细胞色素c的直接电化学

  • 秦玉华 ,
  • 贾若琨 ,
  • 魏庆娟 ,
  • 马丽 ,
  • 关晓辉
展开
  • 东北电力大学化学工程学院;吉林大学超分子结构与材料重点实验室;

收稿日期: 2009-08-28

  修回日期: 2009-08-28

  网络出版日期: 2009-08-28

Fabrication of Polyvinyl Alcohol Arrays and the Direct Electrochemistry of Adsorbed Cytochrome c

  • QIN Yu-hua ,
  • JIA Ruo-kun ,
  • WEI Qing-juan ,
  • MA Li ,
  • GUAN Xiao-hui
Expand
  • (1.College of Chemical Engineering,Northeast Dianli University,Jilin 132012,Jilin,China;2.Key Lab for Supramolecular Structure and Materials,Jilin University,Changchun 130023,China

Received date: 2009-08-28

  Revised date: 2009-08-28

  Online published: 2009-08-28

摘要

利用自组装法以聚苯乙烯有序多孔膜为膜板制备聚乙烯醇微透镜阵列膜.在pH6.89的磷酸盐(PBS)缓冲溶液中,固载在聚乙烯醇微透镜阵列膜修饰的玻碳电极上的细胞色素c于0.072V(vs·Ag/AgCl)处显示一对准可逆的氧化还原峰,是细胞色素c血红素辅基Fe(Ⅲ)/Fe(Ⅱ)电对的特征峰.考察了扫速、溶液pH及支持电解质浓度等因素对细胞色素c电子传递的影响,体系的表观异相电子传递速率常数k0为2.98×10-6cm·s-1.

本文引用格式

秦玉华 , 贾若琨 , 魏庆娟 , 马丽 , 关晓辉 . 聚乙烯醇微透镜阵列的制备及其固载细胞色素c的直接电化学[J]. 电化学, 2009 , 15(3) : 341 -344 . DOI: 10.61558/2993-074X.2007

Abstract

Regular polyvinyl alcohol arrays were prepared with porous polystyrene films by a self-assembly method. Cyt c immobilized on PVA microlens arrays modified glassy carbon electrodes gave a pair of stable,well-defined and quasi-reversible cyclic voltammetric peaks at about 0.072 V (vs. Ag/AgCl) in 0.1 mol/L PBS buffer (pH = 6.89) solution. The effects of scan rate,pH and concentration of buffers on the electrochemical behaviors of Cyt c were studied in detail. The apparent heterogeneous electron transfer rate constant (k0) was evaluated to be 2.98×10-6 cm·s-1.

参考文献

[1]Severion E J,Lewis N S.Relationships among resonant frequency changes on a coated quartz microbalance,thickness changes,and resistance responses of polymer-carbon black composite chemiresistors[J].Anal Chem2000,72:2008-2015. [2]Liu Hai-bo(刘海波),Zhuang zhi-xia(庄峙厦),Chen Cheng-xiang(陈成祥),et al.Luminophore-doped silica nanoparticled as fluorescent probe in protein microarray assay[J].Chinese J Anal Chem(in Chi-nese),2006,34(9):1227-1230. [3]Zhu Ming-zhi(朱明智),Jiang Zhuang-de(蒋庄德).Application of micro/nanofabrication technologies in the ultramicroelectrode fabrication[J].Chinese J Anal Chem(in Chinese),2006,34(12):1794-1800. [4]Oellerich S,Wackerbarth H,Hildebrandt P.Spectro-scopic characterization of non-native conformational states of cytochrome c[J].J Phys Chem B,2002,106:6566-6580. [5]ArsenaultA C.Photonic-crystal full-colour displays[J].Nature Photonics,2007,1:468-472. [6]Bowden E F,Hawkridge F M,Chlebowski J F,et al.Interfacial electrochemistry of cytochrome c at tin oxide,indium oxide,gold,and platinum electrodes[J].J Electroanal Chem,1984,161:355-376. [7]Laviron E,Bard A.General expression of the linear po-tential sweep voltammogram in the case of diffusionless electrochemical systems[J].J Electroanal Chem,1979,101:19-28. [8]Armstrong F A,Hill HA O,Walton N.Direct electro-chemistry of redox proteins[J].Acc Chem Res,1988,21:407-413. [9]Nicholson R S.Theory and application of cyclic voltam-metry of measurement of electrode reaction Kinetics[J].J Anal Chem,1965,37:1351-1355.
文章导航

/