欢迎访问《电化学(中英文)》期刊官方网站,今天是
研究论文

电化学活化玻碳/铋膜电极制备及铅、镉离子敏感分析法

  • 时康 ,
  • 王文婧
展开
  • 厦门大学化学化工学院化学系;

收稿日期: 2010-05-28

  修回日期: 2010-05-28

  网络出版日期: 2010-05-28

Fabrication of Electrochemically Activated Glassy Carbon/Bismuth Film Electrodes for Sensitive Analysis of Pb~(2+) and Cd~(2+)

  • SHI Kang ,
  • WANG Wen-jing
Expand
  • ( Department of Chemistry,College of Chemistry and Chemical Engineering,Xiamen University, Xiamen 361005,Fujian,China

Received date: 2010-05-28

  Revised date: 2010-05-28

  Online published: 2010-05-28

摘要

以电化学活化玻碳为基底电极原位制备金属铋膜电极,用之于分析Pb2+、Cd2+.方法如下:在氢氧化钠溶液中,由恒电位或循环扫描电位方法活化玻碳电极,随后以稀盐酸替代传统的醋酸缓冲液作为分析溶液将Bi3+与Pb2+、Cd2+共沉积在活化玻碳电极表面,再以方波阳极溶出分析法(SWASV)检测金属离子.结果表明:经简单的电化学清洗步骤即可高重现地再生电极表面,大幅度提高检测Pb2+、Cd2+的灵敏度,检测范围也可拓展至高卤素离子含量的样品.

本文引用格式

时康 , 王文婧 . 电化学活化玻碳/铋膜电极制备及铅、镉离子敏感分析法[J]. 电化学, 2010 , 16(2) : 156 -160 . DOI: 10.61558/2993-074X.3338

Abstract

The application of electrochemically activated glassy carbon ( GC) in the in-situ preparing of bismuth film electrodes ( BiFEs) to analyze Pb2 + and Cd2 + was investigated. The glassy carbon electrodes were electrochemically activated by either potentiostic or cyclic polarization in 1 mol·L-1 NaOH solution. Experimental results show that employment of HCl solution as the analytical solution not only can reproducibly renew the electrochemically activated GC electrode surface with an electrochemical clear procedure,but also can greatly enhance the sensitivity of BiFes method for analysis of Pb2 + and Cd2 + . The test range thus was extended to the sample containing high chloride anion concentration.

参考文献

[1]Wang J.Stripping analysis at bismuth electrodes:A re-view[J].Electroanalysis,2005,17:1341-1346. [2]Svancara I,Baldrianova L,Tesarova E,et al.Recent ad-vances in anodic stripping voltammetry with bismuth-modified carbon paste electrodes[J].Electroanalysis,2006,18:177-185. [3]Hocevar S B,Wang J,Deo R P,et al.Potentiometric stripping analysis at bismuth-film electrode[J].Electro-analysis,2002,14:112-115. [4]Pauliukaite R,Hocevar S B,Ogorevc B,et al.Character-ization and applications of a bismuth bulk electrode[J].Electroanalysis,2004,16:719-723. [5]Kefala G,Economou A,Voulgaropoulos A,et al.A study of bismuth-film electrodes for the detection of trace met-als by anodic stripping voltammetry and their application to the determination of Pb and Zn in tapwater and hu-man hair[J].Talanta,2003,61:603-610. [6]Baldrianova L,Svancara I,Vlcek M,et al.Effect of Bi(III)concentration on the stripping voltammetric re-sponse of in situ bismuth-coated carbon paste and gold electrodes[J].Electrochim Acta,2006,52:481-490. [7]Hutton E A,Hocevar S B,Ogorevc M.Ex situ prepara-tion of bismuth film microelectrode for use in electro-chemical stripping microanalysis[J].Anal Chim Acta,2005,537:285-292. [8]Guo H S,Li Y H,Xiao P F,et al.Determination of trace amount of bismuth(III)by adsorptive anodic stripping voltammetry at carbon paste electrode[J].Anal Chim Acta,2005,534:143-147. [9]Morfobos M,Economou A,Voulgaropoulos A.Simultane-ous determination of nickel(II)and cobalt(II)by square wave adsorptive stripping voltammetry on a rota-ting-disc bismuth-film electrode[J].Anal Chim Acta,2004,519:57-64. [10]Kachoosangi R T,Banks C E,Ji X,et al.Electroanalyt-ical determination of cadmium(II)and lead(II)using an in-situ bismuth film modified edge plane pyrolytic graphite electrode[J].Anal Sci,2007,23:283-289. [11]Wang J,Lu J M,Hocevar S B,et al.Bismuth-coated carbon electrodes for anodic stripping voltammetry[J].Anal Chem,2000,72:3218-3222. [12]Wang J,Lu J M.Bismuth film electrodes for adsorptive stripping voltammetry of trace nickel[J].Electrochem Comm,2000,2:390-393. [13]Hocevar S B,Svancara I,Vytras K,et al.Novel elec-trode for electrochemical stripping analysis based on carbon paste modified with bismuth powder[J].Elec-trochimi Acta,2005,51:706-710. [14]Liu G,Lin Y,Tub Y,et al.Ultrasensitive voltammetric detection of trace heavy metal ions using carbon nano-tube nanoelectrode array[J].Analyst,2005,130:1098-1101. [15]Malakhova N A,Stojko N Y,Brainina K Z.Novel ap-proach to bismuth modifying procedure for voltammetric thick film carbon containing electrodes[J].Electro-chem Comm,2007,9:221-227. [16]Krolicka A,Bobrowski A,Kowal A.Effects of electro-plating variables on the voltammetric properties of bis-muth deposits plated potentiostatically[J].Electroanal-ysis,2006,18:1649-1657. [17]Yang M L,Hu Z B.Electrodeposition of bismuth onto glassy carbon electrodes from nitrate solutions[J].J Electroanal Chem,2005,583:46-55. [18]Krolicka A,Bobrowski A.Bismuth film electrode for a-dsorptive stripping voltammetry-electrochemical and microscopic study[J].Electrochem Comm,2004,6:99-104. [19]Hocevar S B,Ogorevc B,Wang J,et al.A study on op-erational parameters for advanced use of bismuth film electrode in anodic stripping voltammetry[J].Electroa-nalysis,2002,14:1707-1712. [20]Shi K,Hu K,Wang S,et al.Structural studies of elec-trochemically activated glassy carbon electrode:Effects of chloride anion on redox responses of copper deposi-tion[J].Electrochimica Acta,2007,52:5907-5913.
文章导航

/